DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory 
2-16
Upgrade the software and hardware 
2
For high or critical reliability:
1. Type upgrade software G3V8r.xx.x.xxx.x no-calls (entire alphanumeric 
string of new software version) and press 
Enter
. At the prompt, press 
Enter
 
to save translations and attempt to preserve calls across the interchange.
For all reliabilities:
2. After the system resets, log in as craft
3. Check for the 
Translation Corruption Detected
 message before 
proceeding with the upgrade. If corruption is detected, refer to 
 in 
 
to correct the problem. 
!
CAUTION:
Do not continue with the upgrade until the translations errors are 
corrected. 
Reset SPE status (H/C only)
1. Type status SPE and press 
Enter
. Wait until the 
Standby Handshake
 
field displays up, which takes about 3 minutes.
2. Type reset spe-standby 4 and press 
Enter
.
NOTE:
You can continue the process while the SPE is resetting.
Set Daylight Savings Rules
You can set up to 15 customized daylight savings time rules. If you have cabinets 
in several different time zones, you can set up rules for each on a location basis. 
A daylight savings time rule specifies the exact time when you want to transition 
to and from daylight savings time. It also specifies the increment at which to 
transition. 
NOTE:
The default daylight savings rule is 0, no daylight savings.
1. Type change daylight-savings-rules and press 
Enter
.