DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Upgrading R5r/R6r/R7r to R8r without Adding Memory
2-8
Upgrade the software and hardware
2
Disable Scheduled Maintenance and Alarm
Origination to INADS
Origination to INADS
NOTE:
Make sure scheduled daily maintenance does not interfere with the
upgrade.
upgrade.
1. Type change system-parameters maintenance and press
Enter.
2. If scheduled maintenance has begun, set the
Stop Time
field to 1 minute
after the current time.
or
If scheduled maintenance has not begun, set the
Start Time
field to a
time after the upgrade is completed. For example, if you start the upgrade
at 8:00 p.m. and the upgrade takes 90 minutes, set the
at 8:00 p.m. and the upgrade takes 90 minutes, set the
Start Time
field
to 21:30.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate
alarms, resulting in unnecessary trouble tickets.
alarms, resulting in unnecessary trouble tickets.
3. Type n in the
Alarm Origination
field and press
Enter
if the field is not
set to neither.
NOTE:
For some software loads
, set the
Cleared Alarm Notification
and
Restart Notification
fields to n before pressing
Enter
.
Check Link Status
1. Type display communication-interface links and press
Enter
. Write down
all enabled links.
2. Type status link
number and press
Enter
. Repeat this step for all links.
3. Write down which links are in service.