Axis Communications Network Print Servers Manuale Utente

Pagina di 170
Configuration Possibilities
112
AXIS 5500 / AXIS 5550 User’s Manual
The AXIS 5500/AXIS 5550 solution to this problem is to assign a 
character set conversion filter to a logical printer, and then link that 
logical printer to the host causing the problem.
You select your desired conversion filter by setting the Character Set 
Conversion (PRx_CSET.) parameter. The output from the conversion filter 
is always IBM PC Set 2 (Code Page 437), and this is the character set the 
printer must be set up for.
Example:
In order to direct print jobs to the printer connected to the AXIS 
5500/AXIS 5550, you should assign the host to a separate logical printer, 
and install a character set conversion filter.
Follow the instructions below to change the conversion filter:
1. From the print server’s internal Web page, select 
Admin | Logical 
Printers.
2. Select the 
PR1 tab.
3. Set the parameter 
Physical Port to USB1.
4. Set the parameter 
Character Set Conversion to ISO>IBM.
5. Click the 
OK button.
6. Select the 
PR2 tab.
7. Set the parameter 
Physical Port to USB1.
8. Set the parameter 
Character Set Conversion to DEC>IBM.
9. Click the 
OK button.
The ISO 8859-2 printer data that is sent to logical printer PR1 converts to 
IBM PC Set 2 and is printed on USB1. Similarly, the DEC printer data that 
is sent to logical printer PR2 converts to IBM PC Set 2 and is printed on 
USB1.
Adding Strings Before
and After Print Jobs
These string functions provide a way to send printer control commands 
before and after each print job. They may be specified individually for 
each logical printer.
All strings are entered as hexadecimal byte values.
Your network contains a host using the character set ISO 8859-2 and a host using the 
character set DEC.