Axis Communications Network Print Servers Manuale Utente

Pagina di 170
Configuration Possibilities
114
AXIS 5500 / AXIS 5550 User’s Manual
Follow the instructions below to substitute command strings:
1. From the print server’s internal Web page, select 
Admin | Logical 
Printers.
2. Select the 
PR1 Web page.
3. Enter the string 
01 0A 02 0D 0A in the String Substitutions text field.
4. Click the 
OK button.
This conversion is the default setting for logical printers PR5 through 
PR8.
Example:
Follow the instructions below to substitute command strings:
1. From the print server’s internal Web page, select 
Admin | Logical 
Printers.
2. Select the 
PR2 tab.
3. Enter the string 
01 0A 02 0D 0A 03 1B 47 31 02 1B 59 in the String 
Substitutions text field.
Click the 
OK button.
Note:
Hex Code
Explanation
01
length of the string you want to replace
0A
the string you want to replace
02
length of the substitute string
0D 0A
the substitute string
Assume that you want to replace the UNIX/Linux New Line (hex 0A) with an Carriage 
Return/Line Feed (hex 0D 0A), and the printer command 
E
C
G1
 (hex 1B 47 31) with 
E
C
Y
(hex 1B 59) for logical printer PR2.
Hex code
Explanation
01
length of the UNIX/Linux New Line command
0A
the UNIX/Linux New Line command 
02
length of the Carriage Return/Line Feed command
0D 0A
the Carriage Return/Line Feed command 
03
length of the printer command to replace
1B 47 31
the printer command to replace
02
length of the new printer command
1B 59
the new printer command
Extensive use of string substitutions will naturally decrease the throughput 
rate of the AXIS 5500/AXIS 5550.