Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Motor does not start 
or a breaker trips.
1.  Compressed air to the machine is not at 57 
PSI.
2.  Sanding motor is not on (conveyor motor).
3.  Emergency  stop  push-button  is  engaged/
faulty.
4.  Air pressure safety switch is at fault.
5.  Switch disabling key is removed (conveyor 
motor).
6.  Plug/receptacle  is  at  fault  or  wired  incor-
rectly.
7.  Start capacitor is at fault.
8.  Conveyor speed dial is at fault.
9.  Motor connection wired incorrectly.
10. Wall fuse/circuit breaker is blown/tripped.
11. Thermal overload relay has tripped.
12. Contactor  not  getting  energized/has  burnt 
contacts.
13. Power supply switched OFF or is at fault.
14. Wiring is open/has high resistance.
15. Motor  ON  button  (sanding  motor)  or  ON/
OFF switch (conveyor motor) is at fault.
16. Centrifugal switch is at fault.
17. Motor is at fault.
1.  Connect clean, dry compressed air to the machine at 
57 PSI.
2.  Turn sanding motor on before conveyor motor.
3.  Rotate clockwise slightly until it pops out/replace it.
4.  Test/replace air pressure safety switch; adjust (
Page 
33).
5.  Install switch disabling key.
6.  Test for good contacts; correct the wiring.
7.  Test/replace if faulty.
8.  Test/replace if faulty.
9.  Correct motor wiring connections.
10. Ensure  circuit  size  is  suitable  for  this  machine; 
replace weak breaker.
11. Turn cut-out dial to increase working amps and push 
the reset pin. Replace if tripped multiple times (weak 
relay).
12. Test for power on all legs and contactor operation. 
Replace unit if faulty.
13. Ensure power supply is switched on; ensure power 
supply has the correct voltage.
14. Check  for  broken  wires  or  disconnected/corroded 
connections, and repair/replace as necessary. 
15. Replace faulty ON button or ON/OFF switch.
16. Adjust/replace the centrifugal switch if available.
17. Test/repair/replace.
Machine  has  vibra-
tion  or  noisy  opera-
tion  (a  metallic 
"thump"  sound  dur-
ing operation is nor-
mal).
1.  Motor or component is loose.
2.  Motor mount loose/broken.
3.  Motor fan is rubbing on fan cover.
4.  Motor bearings are at fault.
5.  Centrifugal switch at fault.
1.  Inspect/replace stripped or damaged bolts/nuts, and 
re-tighten with thread locking fluid.
2.  Tighten/replace.
3.  Replace  dented  fan  cover;  replace  loose/damaged 
fan.
4.  Test by rotating shaft; rotational grinding/loose shaft 
requires bearing replacement.
5.  Replace.
troubleshooting