Grizzly G0503 Manuale Utente

Pagina di 76
Model g0503 (Mfg. since 12/08)
-13-
your Shop circuit capacity
always  check  to  see  if  the  wires  in  your  circuit 
are capable of handling the amperage draw from 
your machine, as well as any other machines that 
could be operating on the same circuit. if you are 
unsure, consult a qualified electrician. 
figure 4. a power disconnect is preferable to 
high current plugs and receptacles.
connection Type
Because  of  the  high  amperage  draw  from  this 
machine,  we  recommend  that  you  hardwire  it 
directly to your circuit breaker and install a locking 
shut-off  lever  (see 
figure  4)  near  the  machine 
as  a  way  to  quickly  disconnect  the  power  and 
prevent accidental starting. we do not recom-
mend using an extension cord with this machine.
in  the  event  of  an  electrical  short,  grounding 
reduces the risk of electric shock by providing a 
path  of  least  resistance  to  disperse  electric  cur-
rent.  this  machine  must  be  equipped  with  an 
electric  cord  that  has  an  equipment  grounding 
conductor.  this  conductor  must  be  grounded  in 
accordance with all local codes and ordinances. 
improper connections of the electrical-grounding 
conductor  increases  the  risk  of  electric  shock. 
Check  with  a  qualified  electrician  or  one  of  our 
service  personnel  if  you  do  not  understand 
the  grounding  instructions,  or  if  you  doubt  the 
machine is properly grounded.
Grounding
Electrocution or fire could 
result  if  this  machine  is 
not  grounded  correctly 
or  if  your  electrical  con-
figuration  does  not  com-
ply  with  local  and  state 
codes. Ensure compliance 
by  checking  with  a  quali-
fied electrician!
Because  of  the  high  amperage  draw  from  this 
machine, we do not recommend the use of exten-
sion cords. instead, position your equipment near 
installed  wiring  to  eliminate  the  need  for  exten-
sion cords.
Extension cords
when  using  a  phase  converter,  the  power  from 
the  manufactured  power  leg  (sometimes  called 
the  wild  wire)  can  fluxuate.  Connect  the  manu-
factured  power  leg  to  the  s  terminal  to  prevent 
damage  to  the  transformer.  the  wire  from  the  s 
terminal  can  handle  some  fluxuation  because  it 
goes directly to the motor. the power going to the 
r  and  t  terminals  goes  to  the  transformer  and 
must be consistent to prevent damage.
phase converter