Advanced Troubleshooting
312667B
21
General Problem: Low or Fluctuating Output
Specific Problem
Cause
Solution
Pump cycles, but output is low or 
surging.
See Basic Troubleshooting
page 11.
Worn or obstructed inlet and 
outlet valves.
Check for worn pump valves as follows:
Prime sprayer with paint. Turn the Prime/Spray valve 
to SPRAY position. Turn pressure control fully 
clockwise.
Trigger spray gun briefly.
When spray gun trigger is released pump should 
cycle momentarily and stop.
If pump continues to cycle, pump valves may be 
worn or obstructed.
For replacement inlet and outlet valve kits, see List 
of Kits
, page 26.
Prime/Spray valve is leaking out 
drain line when Prime/Spray 
valve is in SPRAY position.
Check Prime/Spray valve for debris trapped on seat 
and for worn parts. Torque to 130-180 in-lb 
(15.8-18.1 N•m). Replace if parts are worn using 
Prime/Spray Valve Kit, page 26.
Voltage from electrical outlet is 
too low. Low voltages reduce 
sprayer performance.
Check voltage of outlet. Meter must read 85 to 130V 
AC.
Extension cord is too long or not 
heavy enough gauge.
Replace extension cord.
See Grounding and Electrical Requirements
page 6.
Leads from motor or pressure 
switch to control board are 
damaged, loose, pinched, or 
overheated.
Be sure terminals are centered and firmly 
connected. Inspect for pinched wiring and wiring 
insulation and terminals for signs of overheating. 
Replace any loose terminals or damaged wiring. 
Securely reconnect terminals.
Motor brushes are worn.
Check length of BOTH brushes (brushes do not 
wear evenly on both sides of the motor). Brush 
length must be 0.25 in. (6.4mm). If brushes are worn 
replace motor using Motor Kit, page 26.
Motor brush springs are broken.
If springs are broken, replace motor using Motor Kit
page 26.
Motor brushes are binding in 
brush holders.
Clean brush holders. Remove carbon dust with small 
cleaning brush.
Motor stops before sprayer 
reaches correct pressure (stall 
pressure is too low).
Replace pressure control using Pressure Control 
Switch Kit
, page 26.
Control board is damaged.
CAUTION: Do not perform 
control board diagnostics until 
you have determined the 
armature is good. A damaged 
armature can burn out a good 
control board.
See Control Board Diagnostics, page 25. If 
damaged, replace control board using Control 
Board Kit
, page 26.