Graco Inc. 261820 Manuale Utente
Advanced Troubleshooting
22
312667B
Motor runs and pump cycles,
but pressure does not build up.
but pressure does not build up.
Intake valve or outlet valve is
not seating properly.
not seating properly.
Remove and clean inlet valves and outlet valves.
Replace if necessary. See List of Kits, page 26.
Replace if necessary. See List of Kits, page 26.
Pump packings are worn or
damaged.
damaged.
Check for leaking around pump.
ProX7 and ProX9: Replace pump packings. See
List of Kits, page 26.
List of Kits, page 26.
X5 and X7: Replace complete pump. See List of
Kits, page 26.
Kits, page 26.
Specific Problem
Cause
Solution
General Problem: Excessive Pressure Build Up
Specific Problem
Cause
Solution
Prime/Spray Valve actuates
automatically, relieving
pressure through drain tube.
automatically, relieving
pressure through drain tube.
Pressure control switch has
pinched wires.
pinched wires.
Replace pressure control switch using Pressure
Control Switch Kit, page 26.
Control Switch Kit, page 26.
Water or paint entered
pressure control switch or
shorted control board.
pressure control switch or
shorted control board.
Use Pressure Control Switch Kit, to replace
switch. See List of Kits, page 26.
switch. See List of Kits, page 26.
Control board failed.