Temperature Control Diagnostic Codes 
10
312066Z
E03: No zone current
1.
Check for tripped circuit breaker inside electrical 
cabinet or at power source for that zone. Replace 
circuit breaker if it trips habitually.
2.
Check for loose or broken connection at that zone.
3.
Exchange zone module with another one. Turn 
zone on and check for error (see page 38). If error 
disappears, replace faulty module.
4.
If E03 occurs for all zones, the contactor may not be 
closing. Verify wiring from heater control to contac-
tor coil.
a.
Hose zone: test hose continuity, page 43.
b.
Transformer Secondary Check, starting on 
page 45.
E04: Fluid Temperature Sensor 
(FTS) or thermocouple 
disconnected
1.
Check temperature sensor connections to long 
green connector (B) on temperature control module, 
page 37. Unplug and re-plug sensor wires.
2.
Test fluid temperature sensor continuity with ohm-
meter, page 8.
3.
If an error occurred for the hose zone, check FTS 
connections at each section of hose.
4.
If an error occurred for the hose zone, test FTS by 
plugging directly into machine.
5.
To verify heater control module is not causing the 
problem, use a wire to short-circuit the two pins cor-
responding to the FTS (red and yellow for A or B 
zone, red and purple for hose). The display will 
show the control heater module temperature.
6.
If an error occurred for the hose zone, temporarily 
use the current control mode. Refer to Reactor 
Operation manual 312062.
E05: Circuit board overheated
1.
Check that fan above electrical cabinet is operating.
2.
Check that electrical cabinet door is properly 
installed. 
3.
Check for obstructions blocking cooling holes in bot-
tom of electrical cabinet. 
4.
Clean heatsink fins behind heater control modules.
5.
Ambient temperature may be too high. Allow Reac-
tor to cool by moving to a cooler location.
E06: Communication cable 
unplugged
1.
Unplug and re-plug cable that connects heater con-
trol module to heater module.
2.
Replace communication cable if problem persists.
When a no current error occurs, the LED on the 
specific zone’s module turns red when the error is 
displayed.
TI10964a
F
D
Each module has an on-board temperature sensor. 
Heat is turned off if module temperature exceeds 
185°F (85°C) within the heater module.