Motor Control Diagnostic Codes 
12
312066Z
E21: No component A 
transducer
1.
Check transducer A connection at J3 on motor con-
trol board, page 34, and clean contacts.
2.
Reverse A and B transducer connections. If error 
moves to transducer B (E22), replace transducer A, 
page 36. If error does not move, replace motor con-
trol board, page 34.
E22: No component B 
transducer
1.
Check transducer B connection at J8 on motor con-
trol board, page 35, and clean contacts.
2.
Reverse A and B transducer connections. If error 
moves to transducer A (E21), replace transducer B, 
page 36. If error does not move, replace motor con-
trol board, page 34.
E23: High fluid pressure
1.
Relieve pressure. Verify low pressure with analog 
gauges. Turn main power OFF 
 then ON 
. If error persists, do checks below.
1.
Check the jumpers and the wiring. Check jumper on 
motor control board J10 for E20 and E-XP1, or J7 
for E30 and E-XP2, pins 7-10, page 34.
2.
Remove, clean and re-install the pressure trans-
ducer leads
If the jumpers and the wiring are in good working condi-
tion and you still have the error, then you will need to 
replace the “A” and “B” pressure transducers.
3.
To determine if it’s the “A” or the “B” transducer, you 
will need a known good Reactor pressure trans-
ducer to use as a “test” transducer. The test is done 
without removing the existing pressure transducers 
from the fluid manifold.
a.
Unplug the “A” transducer from the Motor con-
trol board socket (page 36) and replace with 
“test” transducer.
b.
Turn on the Reactor master power.
If the error is gone, turn off the Reactor main 
power, remove test transducer, and replace “A” 
transducer.
If the error persists, unplug the “test” transducer 
from the “A” socket, and reinstall the “A” pres-
sure transducer back into the “A” socket. 
Repeat this test procedure on the “B” side.
4.
If the error persists and no root cause is found 
through the above testing, replace the motor control 
board, page 34.
E24: Pressure Imbalance
Fast E24 Errors
Fast E24 errors occur:
within 10 seconds of turning the pumps on, or
as soon as you trigger the gun.
Causes of Fast E24 Errors
one side of the gun is plugged.
a pressure transducer has failed.
damaged pump seals or check valve.
no feed pressure or empty material drum
plugged heater.
plugged hose.
plugged manifold.
one PRESSURE RELIEF/SPRAY valve is leaking or 
is set to PRESSURE RELIEF/CIRCULATION 
If the pressure difference between components A 
and B exceeds 500 psi (3.5 MPa, 35 bar), an E24 
will occur. This default value is adjustable; see the 
operation manual.
E24 can be an alarm or a warning, as desired. Set 
DIP switch on motor control board ON for alarm, 
OFF for warning. See page 34.