Henkel 97504 Manuale Utente

Pagina di 94
70 
 
3    Operation 
3.7.5 Dispense 
time 
  This menu item is only available if Timed mode has been selected. 
 
When set to Time mode, the dispensing station delivers product during a pre-set 
time span after the meter-mix dispense gun has been actuated. (for Operating mode 
setup see previous menu). 
Dispense time setup 
•  With the dispensing station in ready state, push OK button 4 times - display 
indicates Operating mode.. 
 
 
• Push ALT button to go to Dispense time mode. 
 
 
•  Use arrow keys to enter desired value. 
Arrow key assignment / setting range: 
left: -1.0; right: +1.0; up: +0.1; 
down: -0.1; setting range: 0.1 – 10.0 
• Push OK button to save the setting – display indicates "next menu item". Push 
ESC key to leave the operator menu – display indicates Operation
Operational Mode
Cont. Mode
OK/ESC
*
Dosing Time
5.3 sec.
OK/ESC
*