Bunn LCC-2 LP Manuale Utente

Pagina di 26
20
 
LCD DISPLAY 
 CALIBRATION MODE 
 DESCRIPTION
CALIBRATING THE DISPENSER
Left (Regular) Pump Cal.
Set  PRIME-NORMAL-RINSE  switch 
to  PRIME  position.  Press  and  hold 
Regular Dispense Switch until pump 
stops (20 sec.) Refer to Field Calibration 
of the Concentrate Pumps.
MENU
(-)
(+)
C 1  r u n
NOTE: The LCA-2 LP is calibrated at the factory and does not normally need to be re-calibrated. To enter the 
Calibration Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position and then hold the “MENU” 
switch down for 10 seconds.
Left (Regular) Pump Cal.
Enter mL collected from the 20 sec. 
test above.
Default = 22
Range = 18 - 26mL
MENU
(-)
(+)
C 1    2 2
Right (Decaf) Pump Cal.
Set PRIME-NORMAL-RINSE switch to 
PRIME position. Press and hold Decaf 
Dispense Switch until pump stops (20 
sec.) Refer to Field Calibration of the 
Concentrate Pumps.
MENU
(-)
(+)
C 2  r u n
Right (Decaf) Pump Cal.
Enter mL collected from the 20 sec. 
test above.
Default = 22
Range = 18 - 26mL
MENU
(-)
(+)
C 2    2 2
Left (Regular) Water Rate
Set PRIME-NORMAL-RINSE switch to 
RINSE position. Press and hold Regular 
Dispense Switch until flow stops (20 
sec.) Refer to Field Calibration of the 
Concentrate Pumps.
MENU
(-)
(+)
C 3  r u n
Left (Regular) Water Rate
Enter Liters collected from the 20 sec. 
test above.
Default = 1.08
Range = 0.95 - 1.120 Liters
MENU
(-)
(+)
C 3  1. 0 8