Bunn LCC-2 LP Manuale Utente
22
LED DISPLAY
ERROR
DESCRIPTION/TROUBLESHOOTING
TROUBLESHOOTING GUIDE
Error Codes
When an error has occurred, all Door LED’s will be flashing. Open the Door to access the LED Display and record
the Error Code. Refer to the list of Error Codes below to identify the problem. A troubleshooting guide is provided
to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after
exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
Left (Regular) Pump Failed
Left Motor or RPM Sensor Failure.
Check motor and RPM sensor wires
for shorts or open connections.
MENU
(-)
(+)
E C 0 0 1
Right (Decaf) Pump Failed
Right Motor or RPM Sensor Failure.
Check motor and RPM sensor wires
for shorts or open connections.
MENU
(-)
(+)
E C 0 0 2
Heating Time Too Long
Tank Heater ON Continuous For More
Than 1 Hour. Check heater wires for
open connections.
MENU
(-)
(+)
E C 0 0 3
Fill Time Too Long
Fill Valve ON Continuous For More Than
15 Minutes. Water turned OFF. Refill
Valve disconnected. Faulty Valve.
MENU
(-)
(+)
E C 0 0 4
39288 083106
Cool Temp Sensor Above 75°F (24°C)
For More Than 4 Hours. Cabinet Door
open or faulty seal. Check T.E. Unit
wires for shorts or open connections.
Air Filter plugged or blocked. Ambient
Temperature too high. >90°F (32°C)
MENU
(-)
(+)
E C 0 0 5
Heat Sink Temp Too High
Heat Sink Temp Higher Than 190°F
(88°C). Air Filter plugged or blocked.
Ambient Temperature too high. >90°F
(32°C)
MENU
(-)
(+)
E C 0 0 6
Cool Time Too Long