Bunn LCC-2 LP Manuale Utente

Pagina di 26
22
 
LED DISPLAY 
 ERROR 
 DESCRIPTION/TROUBLESHOOTING
TROUBLESHOOTING GUIDE
Error Codes
When an error has occurred, all Door LED’s will be flashing. Open the Door to access the LED Display and record 
the Error Code. Refer to the list of Error Codes below to identify the problem. A troubleshooting guide is provided 
to suggest probable causes and remedies for the most likely problems encountered.  If the problem remains after 
exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
Left (Regular) Pump Failed
Left  Motor  or  RPM  Sensor  Failure. 
Check motor and RPM sensor wires 
for shorts or open connections.
MENU
(-)
(+)
E C  0 0 1
Right (Decaf) Pump Failed
Right Motor or RPM Sensor Failure. 
Check motor and RPM sensor wires 
for shorts or open connections.
MENU
(-)
(+)
E C  0 0 2
Heating Time Too Long
Tank Heater ON Continuous For More 
Than 1 Hour. Check heater wires for 
open connections.
MENU
(-)
(+)
E C  0 0 3
Fill Time Too Long
Fill Valve ON Continuous For More Than 
15 Minutes. Water turned OFF. Refill 
Valve disconnected. Faulty Valve.
MENU
(-)
(+)
E C  0 0 4
39288 083106
Cool Temp Sensor Above 75°F (24°C) 
For More Than 4 Hours. Cabinet Door 
open  or  faulty  seal.  Check  T.E.  Unit 
wires for shorts or open connections. 
Air Filter plugged or blocked. Ambient 
Temperature too high. >90°F (32°C)
MENU
(-)
(+)
E C  0 0 5
Heat Sink Temp Too High
Heat  Sink  Temp  Higher  Than  190°F 
(88°C). Air Filter plugged or blocked. 
Ambient Temperature too high. >90°F 
(32°C)
MENU
(-)
(+)
E C  0 0 6
Cool Time Too Long