3.5.2 Initial configuration with AT commands 
You can perform the initial configuration alternatively with the software HSComm as 
described in the previous chapter. 
1. 
Start your terminal program or the terminal window of HSComm. 
2. 
Set the serial interface settings to the standard values: 19200 baud, 8 data bits, 1 
stop bit, no parity: 
AT**BAUD=19200 
AT**FORMAT=8N1 
3. 
If the device is in an undefined state, reset it optionally to the factory settings 
first: 
AT&F&WZ 
AT**DEFAULT 
4. 
Enter the PIN. 
Example: Entering the PIN 1234: 
AT**PIN=1234 
If the PIN of the SIM card is deactivated, enter only AT**PIN=. 
5. 
Check the field strength of the GSM signal: (see Chap. 3.9) 
AT**SIGNAL? 
The GSM signal should have a field strength of at least 12.  
For lower values or the value 99 you will need to change the antenna location. 
 
Note 
After changing the antenna location, wait 5 to 10 seconds. Only 
now will the device display the field strength correctly. 
3.6 
Restart 
For the restart, you must insert the SIM card and restart the device. The device will reini-
tialize and login into the GSM network. 
3.6.1 Procedure: Insert SIM card 
 
Switching the SIM Card 
Prior to switching the SIM card, you must change or delete the PIN 
before inserting the new SIM card. 
Otherwise, the SIM card will be blocked after three unsuccessful 
login attempts. 
 
 
Notes: 
  Only 3V cards may be used. 
  Changing the SIM card is only permitted when the device is 
switched off.