Insys GSM 4.2 I4 11-02-01-03-01.038 Manuale Utente

Codici prodotto
11-02-01-03-01.038
Pagina di 69
INSYS GSM 4.2 I4 
Operating Modes 
 
Dez-06 
            31 
The data connection remains established, while the entered extended INSYS AT** 
commands are processed at the remote device. The device changes back to connection 
mode with AT**EXIT.  
If it has been set, the remote configuration password is queried before changing to the 
remote configuration mode. 
4.2.4 SMS configuration  
You can also send the extended INSYS AT** commands to the device via SMS. (see 
Chap. 6.2.4) 
The commands sent via SMS will be executed as soon as the device is in command mode. 
4.3 
Alarm State 
As soon as an alarm input of the device has been activated, existing data and voice con-
nections are terminated. Incoming commands are ignored during the processing of the 
alarm actions. If an input is activated while processing an alarm at the other input, the 
second alarm state is saved and executed subsequently. 
If an connection cannot be established, a re-dial is attempted after one minute until the 
defined maximum number of dial-up attempts is reached. (see Chap. 6.1.3) 
The LED Status is flashing during the (attempted) connection set-up. 
 
4.4 
AT Commands for Switching into another Operating Mode 
*** 
Activate remote configuration mode 
+++ 
Activate online command mode 
ATD 
Establish a connection 
ATH 
Terminate connection 
AT**EXIT 
Exit remote configuration mode 
ATO 
Exit online command mode 
AT**PASSC 
Password for remote configuration 
AT**ESC 
Escape character for remote command mode