Insys GSM 4.2 I4 11-02-01-03-01.038 Manuale Utente

Codici prodotto
11-02-01-03-01.038
Pagina di 69
INSYS GSM 4.2 I4 
Functions and their configuration 
 
Dez-06 
            39 
  Connection set-up for alarm messages via a data connection 
  Connection set-up for security callback 
Possible values are 1 to 12, default value is 3. 
The dispatch will only be attempted once for an acknowledgement SMS after a configu-
ration via SMS.  
 Set number of dialing attempts 
To set the number of dialing attempts in the software HSComm, enter the requested 
number in the tab "Basic settings"  in the group "GSM connections" in the entry field "Di-
aling attempts". 
Pertinent AT commands 
AT**DIAL 
Dial-up attempts for periodic alive or alarm messages 
6.1.4 Auto answer 
After the specified number of ring tones, the device will accept a data call. 
 
Switched off 
2 to 255   
On 
 
 
Note 
Incoming voice calls are automatically accepted when DTMF proc-
essing is enabled. 
 Activate auto answer 
To activate auto answer in the software HSComm, activate the check box "Auto answer" 
in the tab "Basic settings" in the group "GSM connection". 
Pertinent AT commands 
ATS0 
Auto answer 
6.1.5 System monitoring