Insys GSM 4.2 I4 11-02-01-03-01.038 Manuale Utente

Codici prodotto
11-02-01-03-01.038
Pagina di 69
INSYS GSM 4.2 I4 
Functions and their configuration 
 
Dez-06 
            37 
Idle detection 
The device can terminate hanging connections, over which no data is exchanged any-
more, automatically after a specified waiting period. Each character, which is sent via the 
serial interface (both directions), restarts the timer.  
You may enter a waiting time of up to 255 seconds. To deactivate idle detection enter a 
waiting time of 0 seconds. 
Detect field strength intensity 
Use the button "Detect GSM field strength now" to read out the field strength. (see Chap. 
6.1.1) 
Query login state 
The validity of the PIN and the login state are displayed under the control box "PIN ac-
tive" in plain text. (see Chap. 6.1.1 ) 
Configure PIN, service center number and idle detection 
1. 
Start the program HSComm under Windows. 
The configuration software is started and displays the tab "Basic settings".  
2. 
In the group "GSM connection", activate the control box "New PIN" and enter the 
new PIN in the entry field. 
 
 
Note 
The PIN is encrypted. The displayed character is *. 
3. 
To delete the PIN, activate the control box "Delete PIN" in the group "GSM connec-
tion".  
4. 
Enter the service center number (SCN) of the GSM provider in the group "GSM 
connection" in the field "Service center number". Use the international format (e.g. 
Germany: +49...) for entering the number (see Chap.6.1.1). 
5. 
Enter the requested waiting time (in seconds) in the group "GSM connection" in 
the entry field "Idle detection". 
Pertinent AT commands 
AT**PIN 
SIM card PIN 
AT**PROVIDER 
Preferred provider 
AT**SCN 
Service Center Number 
AT**DTC 
Idle connection control (Data Transmit Controller) 
AT+CREG 