Multi Tech Equipment MVH306DS2 Manuale Utente

Pagina di 80
page 28 — mvh306ds2/dsCpas pLaTe COmpaCTOR • OpeRaTiOn and paRTs manuaL — Rev. #7 (02/04/14) 
BaTTeRY ChaRging
 
„
dO  nOT charge battery with the battery cables 
connected to the compactor. The diodes will be damage 
by the high voltage.
 
„
Batteries generate hydrogen gas which 
can be highly explosive. 
dO nOT smoke 
or allow flames or sparks near the battery, 
especially during charging of the battery.
 
„
Charge the battery in a open air environment (plenty of 
ventilation).
 
„
Before charging , remove the cap from each cell of the 
battery.
 
„
Connect the positive (+) lead of the charger to the 
positive (+) terminal of the battery and the negative (-) 
lead of the charger to the negative (-) terminal of the 
battery. 
dO nOT reverse the polarity when charging. 
Reverse polarity will damage the charger rectifier or 
the battery.
 
„
Battery fluid will be lost through continuous charging 
and discharging.
 
„
Discontinue charging if the electrolyte temperature 
exceeds 117° F (45° C).
 NOTICE
During summer much more battery fluid is lost than in 
winter. Before starting, check battery electrolyte levels 
and replenish with distilled water to the upper mark on 
the battery.
MAINTENANCE
BaTTeRY CaBLe COnneCTiOn (Option)
1.  Take off the battery cover by removing the M6 nuts that 
secure the battery holder to the cover.
2.  When removing battery cables, disconnect the ground 
side (normally negative) first (Figure 39).
3.  When installing battery cable connect the ground side 
(normally negative) last.
Figure 39.  Removing Battery Cover
CheCKing FueL FiLTeR
1.  Clean the fuel filter every 3 months or 200 hours.
2.  Replace fuel filter every 6 months or 400 hours.
3.  To clean the fuel filter, loosen the nuts (Figure 40) of 
the fuel cock and pull out the filter from the F.O. tank 
filler port. Wash the filter thoroughly with diesel fuel oil.
4.  Reinstall fuel filter and connect all associated hardware
NUTS
DRAIN
PLUG