Mitsubishi HG-RR Manuale Utente

Pagina di 378
8. HG-JR SERIES 
8 -  12 
 
Servo motor 
 
Item 
HG-JR 1500 r/min series  
(Compatible with 3-phase 400 V AC, low inertia/large capacity) 
701M4 
(B) 
11K1M4 
(B) 
15K1M4 
(B) 
22K1M4 30K1M4 37K1M4 45K1M4 55K1M4 
Power supply capacity 
 
Refer to "Power supply equipment capacity and generated loss of servo amplifiers" 
in Servo Amplifier Instruction Manual. 
Continuous running 
duty (Note 1) 
Rated output  [kW] 
7.0  11  15  22  30  37  45  55 
Rated torque 
[N•m] 
44.6 
70.0 
95.5 
140 
191 
236 
286 
350 
Maximum torque 
 
 [N•m] 
134 210 286 420  573  707  859 1050 
Rated speed (Note 1)   
[r/min] 
1500 
Maximum speed 
 
[r/min] 
3000 
2500 
Instantaneous permissible speed 
[r/min] 
3450 
2875 
Power rate at 
continuous rated 
torque 
Standard  [kW/s] 
113 223 289 401  582  726  596  749 
With an 
electromagnetic brake 
[kW/s] 
101 204 271   
 
 
 
 
Rated 
current   
[A] 
17 31 38 50  68  79  85 110 
Maximum current 
 
[A] 
56 
100 
123 
170 
235 
263 
288 
357 
Moment of inertia J 
Standard [× 10
-4
 kg•m
2
176 220 315 489  627  764 1377 1637 
With an 
electromagnetic brake 
[× 10
-4
 kg•m
2
196 240 336   
 
 
 
 
Recommended load to motor inertia ratio  
(Note 2) 
10 times or less 
Speed/position detector 
 
22-bit encoder common to absolute position/incremental 
(resolution per servo motor revolution: 4194304 pulses/rev) 
Oil seal 
 
 
With 
Insulation class 
 
 
155 (F) 
Structure  
 
Totally-enclosed,  
natural-cooling  
(IP rating: IP67 (Note 3)) 
Totally-enclosed, force-cooling  
(IP rating: IP44 (Note 3)) 
Environment (Note 4) 
Ambient 
temperature 
Operation 0 
˚C to 40 ˚C (non-freezing) 
Storage -15 
˚C to 70 ˚C (non-freezing) 
Ambient 
humidity 
Operation 
80 %RH or less (non-condensing) 
Storage 
90 %RH or less (non-condensing) 
Ambience  
Indoors (no direct sunlight), 
free from corrosive gas, flammable gas, oil mist, dust, and dirt 
Altitude 
 
1000 m or less above sea level 
Vibration resistance 
(Note 5) 
X, Y: 24.5 m/s
2
 
X, Y: 9.8 m/s
2
 
Vibration rank (Note 6) 
 
V10 
Permissible load for 
the shaft (Note 7) 
L [mm] 
85 
116 
140 
140 
Radial [N] 
2450 
2940 
3234 
4900 
Thrust [N] 980 
1470 
1960 
Mass 
Standard [kg] 
53 
62 
86 
120 
145 
165 
215 
240 
With an 
electromagnetic brake 
[kg] 
65 74 97   
 
 
 
 
Cooling fan 
Power 
supply 
Voltage/ 
Frequency 
 
 
 
3-phase 380 V AC to  
480 V AC 
50 Hz/60 Hz 
3-phase 380 V AC 
to 460 V AC 
50 Hz/60 Hz 
Power 
consumption  
[W] 
 
 
 
65 (50 Hz)/85 (60 Hz) 
110 (50 Hz)/ 
150 (60 Hz) 
Rated current 
[A] 
 
 
 
0.12 (50 Hz)/0.14 (60 Hz) 
0.20 (50 Hz)/ 
0.22 (60 Hz)