Mustang Survival MD3091 Manuale Utente

Pagina di 20
MD3091
The left lobe (as worn) of the MD3091 LP 
contains the oral inflator tube assembly-A. 
The right lobe of the LP contains the manual 
inflator assembly-B and the orange whistle-C. .
To become more familiar with the LP 
components:
1.  Open both zippers completely, and place 
the LP on a smooth, flat surface with the 
inflator facing the user.
2.  Ensure the oral inflator dust cap is in the 
stowed position.
3.  Ensure the status pin and the CO
2
 cylinder 
are intact, and the lever is in the up and 
ready position (Figure 6).
4.  If the cylinder is not intact, and/or if the 
status pin is missing or broken, re-arm the 
cylinder and replace the status pin – see 
Re-arming (Figure 7).
5.  Repack the LP – see Repacking.
Prior to Use
Visually inspect the LP prior to use to:
ensure the LP is properly armed
ensure the LP is free of rips, tears, or holes and all seams are securely 
sewn
ensure the fabric, straps, and hardware are free from any defects
READINESS CHECKLIST (MD3196 & MD3091)
When all applicable boxes are checked, the LP is ready for use:
 
F
Beaded manual inflation handle is fastened.
 
F
No rips, tears, or holes, and all seams securely sewn.
 
F
Fabric, straps, and hardware free from defects.
 
F
All zippers, Velcro™, and chest buckle securely fastened.
 
F
MD3196 only: Status indicator is green.
 
F
MD3196 only: Inflator expiry date has not passed.
 
F
MD3091 only: Status pin and cylinder intact, and manual inflation lever 
in the up and ready position.
NOTE: If there are any concerns about the readiness of the MD3196 or 
MD3091, contact the Mustang Survival dealer.
A
B
C
FiGURE 5
Piercing Pin
Status Pin
Inflation Lever
FiGURE 7
CO2 Cylinder  
Inflator Mechanism
Up-and-Ready
Status Pin
Inflation Lanyard
Beaded Manual
Inflation Handle
FiGURE 6
Compact Tactical LP 
Owners Manual
 
3