for Catalyst thumbnail previewing, how to associate Catalyst fixtures to Catalyst media servers
in the patch window, and how to use the patch window to refresh Catalyst media previews.
10.3.1
Configuring DP8000 for Catalyst Preview Thumbnails
In order for the console to properly fetch and display thumnail previews for Catalyst media
servers on a DP8000's FixtureNet network, the FixtureNet adapter for the DP8000 must be
properly configured:
1.
Open the node settings window for the DP8000 that is connected via FixtureNet
to the Catalyst media servers
2.
Select the FixtureNet tab of the node settings window
3.
Ensure that the IP address and subnet settings are appropriate for the network
environment in which the Catalyst media servers are connected. This is similar
to configuring the FixtureNet network adapter for Art-Net and sACN output.
To better ensure connectivity it is recommended that the IP address assigned
to the FixtureNet adapter be within in the same sub-network as the Catalyst
it is receving preview thumnails from.
10.3.2
Patching Catalyst fixtures to Catalyst Media Servers
Once a Catalyst fixture is scheduled in the patch window and patch to a DMX output, the Catalyst
fixture can then be patched to a Catalyst media server that is connected to the FixtureNet network
of any active DP8000 connected to the console. Follow these steps to patch a Catalyst fixture to
a Catalyst media server:
1.
Open the patch window
2.
Select the Catalyst fixture(s) you wish to associate with a Catalyst media
server in the rig
3.
Press the "patch media" button at the top of the patch window
4.
Select the Catalyst tab in the media patch window
5.
Enter the IP Address of the Catalyst media server
6.
Press okay. You will now see the IP address of the Catalyst media server in
the patch window listed for the Catalyst fixtures you selected in step 2. This
will now associate the Catalyst fixtures in your show file with the Catalyst
media servers in the rig as long as the Catalyst media server's IP remains the
same.
!
Caution
If the IP address of a Catalyst Media server in the rig changes you will
need to perform the "patch media" task again.