High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
The controls are, from left to right, the
Go
,
Halt/Back
,
Skip Back
,
Skip Forward
, and
Release
buttons. These function in the same way as their front panel equivalents; see The Main Controls
(p.253)
.
17.2.3
Running Virtual Masters from the Command Line
To run a cuelist on a virtual master from the command line:
List
1
,
Enter
: sends a Go command to cuelist 1.
17.3
Running Multiple Cuelists & Scenes
Because Hog consoles can simultaneously run ten cuelists on masters (and more if virtual masters
and playback wings are used) the question arises as to which master actually has control over a
particular fixture parameter. To decide which master takes precedence Hog 4OS applies the
following rules:
For intensity parameters: by default, intensity parameters are controlled on
a Latest Takes Precedence (LTP) basis, therefore the value of an intensity
parameter that appears in several cuelists will be output from the cuelist with
the highest playback priority; see Changing a Cuelist's Priority (p.267)In addi-
tion, you can assign cuelist options so that a master works on a Highest Takes
Precedence (HTP) basis; this means that if several masters have programming
for the same intensity parameter, the highest programmed level will be output
to stage. For a full discussion of HTP and LTP, see HTP and LTP (p.31).
For position, colour and beam parameters: Hog 4OS deals with position,
colour and beam parameters on a Latest Takes Precedence (LTP) basis. If sev-
eral masters have programming for the same parameter then the value from the
most recently activated master will override the value from previously activated
masters. Parameters that are only programmed into a single master will remain
at that value. When you release the most recently activated master, control will
be returned to the previously activated master. Alternatively you can assert a
previously activated master's parameters so that they override the most recently
High End Systems
264
Section 17: Playback