High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
17.3.2
Asserting One Cuelist Over the Others
When you have several cuelists active at the same time, control of fixture parameters programmed
into one cuelist may be taken by another cuelist that also has programming for that fixture para-
meter. For example, if Cuelist 1 has programming for desk channels 1-3, and Cuelist 2 has pro-
gramming for desk channels 3-6, then running a cue in Cuelist 2 will override the intensity
parameter of desk channel 3.
You may want to return control of desk channel 3 to Cuelist 1 without having to run a cue in
Cuelist 1; this is known as asserting Cuelist 1. Asserting a cuelist forces all fixture parameters
to their programmed value in the cuelist.
To assert parameters on the cuelist attached to Master 3, for example, press and hold the
Choose
key for Master 3, and press the
Assert
key.
The Assert Time
When you assert a cuelist, the parameters that have been asserted change to their new values
over the assert time. The default is 2 seconds, but you can assign your preferred assert time for
each cuelist:
1.
Open
+
Choose
 
 
Options
 
 
Cuelist
2.
Select the
Assert Time
cell:
3.
Set
5
,
Enter
: change the assert time to 5 seconds.
Alternatively, you can assign the Assert Time for all new cuelists in the
Cuelist
pane of the
User
Preferences
window:
Setup
 
 
Preferences
 
 
Cuelist
Tip
If you have assigned an assert time to a cuelist, and you want to revert
to the default assert time, press the Default button adjacent to the Assert
Time cell.
High End Systems
266
Section 17: Playback