VENTING INSTALLATION 
INSTRUCTIONS
Continued
Vertical Termination Configurations
Figures 21 through 24 show four different configurations for verti-
cal termination. 
     Venting with Two 90° Elbows
 
Vertical (V) 
Horizontal (H
1
) + 
 
 
Horizontal (H
2
)
 
5' min. 
2' max.
 
6' min. 
4' max.
 
7' min. 
6' max.
 
8' min. 
8' max.
 
20' max. 
8' max.
Figure  21  -  Vertical  Venting  Configuration  Using  Two  90°  
Elbows with Two Horizontal Runs (Vertical Round High Wind 
Termination Shown)
Venting with One 90° Elbow
  Vertical (V) 
Horizontal (H)
 
5' min. 
2' max.
 
6' min. 
4' max.
 
7' min. 
6' max.
 
8' min. 
8' max.
 
20' max. 
8' max.
Figure 22 - Vertical Venting Configuration Using One 90° Elbow 
(Vertical Round High Wind Termination Shown)
Note: Install restrictor 
into inner collar of 
fireplace as shown.
Venting with Two 90° Elbows
  Vertical (V
1
Horizontal (H)
 
5' min. 
6' max.
 
6' min. 
12' max.
 
7' min. 
18' max.
 
8' min. 
20' max.
Note: Vertical (V
1
) + Vertical (V
2
) = 40' max.
Figure 23 - Vertical Venting Configuration Using Two 90° Elbows 
(Vertical Round High Wind Termination Shown)