Desa (V)TC36P Manuale Utente

Pagina di 40
15
15
www.desatech.com
116192-01C
VENTING INSTALLATION 
INSTRUCTIONS
Continued
Vertical Venting
V = 40' max.
Figure 24 - Vertical Venting Configuration With No Horizontal 
Run (Vertical Round High Wind Termination Shown)
Note: Install restrictor 
into inner collar of 
fireplace as shown.
45° Elbow
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent fireplace has been tested and approved for 
elevations from 0-2000 feet (USA) and elevations from 0-4500 
feet (Canada) .
When installing this fireplace at an elevation above 2000 feet (in 
the USA), you may need to decrease the input rating by changing 
the existing burner orifice to a smaller size. Reduce input 4% for 
each 1000 feet above sea level. Check with your local gas company 
for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in 
Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice 
for your location.
For assistance with any high altitude installation contact DESAʼs 
Customer Service Department at 1-866-672-6040.
VENTING INSTALLATION INSTRUCTIONS
Installation for Vertical Termination (Cont.)
High Altitude Installation