Empire Comfort Systems DVX36DP31(N,P)-1 Manuale Utente

Pagina di 72
25613-0-0309
Page 35
NOTE:  Termination  cap  should  pass  through  the  wall  firestop 
from the exterior of the building. Adjust the termination 
cap to its final exterior position on the building.
Warning: Termination cap must be positioned so that arrow 
is pointing up.
Attach the termination cap with the four wood screws provided. 
Before attachment of the termination, run a bead of silicone sealant 
rated above 250°F on its outside edge too, so as to make a seal to 
the exterior wall.
NOTE:   Wood screws can and should be replaced with appropriate 
fasteners for use on stucco, brick, concrete or other types 
of siding.
CAUTION: If exterior walls are finished with vinyl siding, (or 
materials that could become discolored or warp) it is necessary to 
install a vinyl siding standoff.
The  vinyl  siding  standoff  will  be  installed  between  the  vent 
termination and the exterior wall. See Figure 54. This horizontal vent 
termination bolts onto the flat portion of the vinyl siding standoff, so 
an air space will exist between the wall and the termination cap.
BOLT (4 REQUIRED)
VENT TERMINATION
WOOD SCREWS (4 REQUIRED)
NUT
(4 REQUIRED)
CUT VINYL SIDING AWAY
TO FIT STANDOFF
Figure 54
HORIZONTAL TERMINATION