Desa VM36(B,H) Manuale Utente

Pagina di 32
www.desatech.com
108795-01V
24
troubleshootING
Continued
OBSERVED PROBLEM
Pilot goes out when wall switch 
is ON
Spark ignitor will not light pilot 
after  repeated  triggering  of 
red button
Fireplace produces a clicking/
ticking noise just after burner 
is lit or shut off
POSSIBLE CAUSE
1. Millivolt output on thermo-
pile too high
1. Defective ignitor (no spark 
at electrode)
2. Defective pilot or misaligned 
electrode at pilot (spark at 
electrode)
3. No  gas  or  low  gas  pres-
sure
4. If using propane/LP gas, no 
propane/LP gas in tank
1. Metal  expanding  while 
heating or contracting while 
cooling
REMEDY
1. Replace thermopile
1. Check for spark at electrode 
and  pilot.  If  no  spark  and 
electrode  wire  is  properly 
connected, replace ignitor
2. Using a match, light pilot. If 
pilot lights, turn off pilot and 
trigger the red button again. 
If  pilot  lights,  an  improper 
gas/air mixture caused the 
improper  lighting  and  a 
longer purge period is rec-
ommended. If pilot will not 
light, check gap at electrode 
and  pilot.  Gap  should  be 
1/8" to have a strong spark. 
If okay, replace pilot
3. A)  Check  remote  shut  off 
valves from fireplace. Usu-
ally there is a valve near the 
fireplace  and  sometimes 
there  is  a  valve  near  the 
main.  There  can  be  more 
than  one  valve  between 
fireplace and main
  B)  Low  pressure  can  be 
caused by a variety of situ-
ations such as bent line, or 
gas supplier
4. Check  propane/LP  supply 
and contact local propane/
LP supplier
1. This  is  normal  with  most 
fireplaces.  If  noise  is  ex-
cessive,  contact  qualified 
service person