troubleshootING
Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two 
most common causes of a malfunctioning gas appliance are:
1.  Loose wiring connections
2.  Construction debris clogging pilot and/or gas control valve filter
OBSERVED PROBLEM
Pilot will not light
Pilot will not stay lit
No gas to burner, although wall 
switch and valve are set to the 
ON position
Frequent pilot outage
POSSIBLE CAUSE
1. No  gas  supply  or  shutoff 
valve is OFF
2. Air in gas line
3. Construction  debris  clog-
ging pilot orifice
4. Low gas pressure
5. Control valve knob is not on 
the PILOT position
6. Kinked pilot line
7. Bad valve
8. Vent  damper  not  fully 
open
1. Loose wiring on thermopile 
to regulator valve. No mil-
livolt  current  is  being  sent 
back to regulator
2. If  valve  knob  and  wall 
switch are in the ON posi-
tion,  probable  defective 
regulator valve
3. Vent  damper  not  fully 
open
1. Wall switch wires defective 
or too long
2. Thermopile not generating 
sufficient voltage
1. Pilot flame may be too low, 
causing safety pilot to “drop 
out”
2. Improper venting or exces-
sive blockage
REMEDY
1. Check  to  see  if  you  have 
gas supply
2. Hold regulator control valve 
in the PILOT position for 2 
to 3 minutes to purge air. If 
you smell gas stop and wait 
for  a  few  minutes  before 
trying to light fireplace
3. Remove  debris  and  dirt, 
inspect and clean any other 
possible obstructions
4. Contact your gas supplier
5. Refer  to  section  on  pilot 
lighting
6. Have a qualified technician 
replace pilot line
7. Replace regulator valve (see 
Accessories, page 31)
8. Open vent damper until fully 
locked in OPEN position 
1. Check wiring connections. 
Refer  to  wiring  diagram 
shown in Wall Switch Instal-
lation
, page 11
2. Have a qualified technician 
replace valve
3. Open vent damper until fully 
locked in OPEN position
1. Check  electrical  connec-
tions
2. See  Pilot  will  not  stay  lit
above
1. Clean and adjust pilot flame 
for  maximum  flame  im-
pingement on thermopile
2. Have vent system inspect-
ed,  including  termination 
cap.  Remove  any  restric-
tion or obstruction