Desa VM36(B,H) Manuale Utente

Pagina di 32
www.desatech.com
108795-01V
8
Pre-INstallatIoN PreParatIoN
Continued
FRAMING
1.  Frame appliance enclosure as illustrated 
in Figures 7 and 8.
 
Note: If a wall covering is used to line the 
enclosure, then all measurements must 
be from the surface of the covering.
2.  Place the appliance into the framing and 
secure it.
 
Note: If appliance is to be raised above 
floor  level,  a  platform  must  be  built  to 
support the appliance.
3.  Install  the  supply  line  to  the  appliance 
using a 1/2" NPT black iron gas line ter-
minating 2 
5
/
16
" above the bottom of the 
appliance. The gas line must be installed 
through the lower left side access point or 
alternate access hole in the bottom of the 
appliance (see Figure 19, page 13).
4.  Repack insulation around the gas line to 
cover any remaining openings in the con-
duit sleeve. Prepare the incoming gas line 
with  teflon  tape  or  pipe  joint  compound 
and  hook-up  incoming  gas  line  to  the 
flexible gas line.
 
Note: If 1/2" NPT black iron pipe does not 
mate with fitting at the end of flexible gas 
line, remove fitting and replace with a 37° 
flare 3/4"-12, 1/2" NPT (female) fitting.
 WARNING:  When  finishing
appliance, do not overlap com-
bustible material onto the black
front  face.  Brick,  tile  or  other
noncombustible materials may
be applied to the face provided
that  any  gap  is  between  the
material  used  and  the  face  is
caulked with a noncombustible
caulking.
Figure 7 - Rough Opening for Installing 
in Wall
B
C
A
M36(B,H),
M36P(B,H)
VM36(B,H),
VM36P(B,H)
M42(B,H),
M42P(B,H)
VM42(B,H),
VM42P(B,H)
A
40 
3
/
8
" (102 cm) 
44 
3
/
8
" (112 cm)
B
21 
3
/
8
"  (54.3 cm)  23 
1
/
8
"  (58.7 cm) 
C
41 
1
/
4
" (104.8 cm)  48 
1
/
4
" (122.6 cm) 
Figure 8 - Corner Installation Guidelines
A
B
C
D
M36(B,H),
M36P(B,H)
VM36(B,H),
VM36P(B,H)
M42(B,H),
M42P(B,H)
VM42(B,H),
VM42P(B,H)
A
24 
1
/
2
" (62.2 cm) 
27 
9
/
16
" (70 cm)
B
73 
7
/
8
" (187.6 cm) 
83 
7
/
8
" (213 cm) 
C 52 
3
/
16
" (132.6 cm)  59 
5
/
16
" (150.6 cm)
D
17 
1
/
4
" (43.8 cm)
19 
1
/
2
" (49.5 cm)
These Dimensions Allow for a 3/4" 
Clearance at Sides and Back of Fireplace. 
However, 0" Clearance is Permitted.
3/4" Clearance Not Required 