VENTING INSTALLATION 
INSTRUCTIONS
Continued
  WARNING:  Do  not  recess 
vent termination into any wall. 
This will cause a fire hazard.
6. 
Noncombustible Exterior Wall:
 Position the 
horizontal vent cap in the center of the 8 
1
/
2
"
round hole and attach to the exterior wall with 
four wood screws provided. Before attaching 
the vent cap to exterior wall, run a bead of 
non-hardening mastic (pliable sealant) around 
the outside edges to make a seal between it and 
the outside wall. Note: The four wood screws 
provided should be replaced with appropriate 
fasteners for stucco, brick, concrete or other 
types of sidings.
Combustible Exterior Wall:
 For vinyl siding, 
stucco or wood exteriors, a siding standoff may 
be installed between the vent cap and exterior 
wall. The siding standoff prevents excessive 
heat  from  damaging  the  siding  materials. 
Siding material must be cut to accommodate 
standoff. Bolt the vent cap to the standoff. Ap-
ply non-hardening mastic around outside edge 
of standoff. Position the standoff/cap assembly 
in the center of the 10 
3
/
4
" square hole and attach 
to exterior wall with wood screws provided (see 
Figure 11). The siding standoff must sit flush 
against the exterior fascia material.
7. 
Combustible Exterior Wall Only:
 Slide the wall 
firestop over the vent pipe before connecting 
horizontal run to vent cap (see Figure 12).
8.  Carefully move fireplace, with vent assembly 
attached, toward wall and insert vent pipe 
into horizontal termination. The pipe overlap 
should be a minimum of 1
1
/
4
" (see Figure 13, 
page 12).
9. 
Combustible Exterior Wall Only:
 Slide wall 
firestop against interior wall surface and attach 
with screws provided. See Figure 13, page 12, 
for horizontal termination details.
10.  Place fireplace into position and shim with 
noncombustible material if needed. Nail or 
screw side flanges to framing to secure unit in 
place. IMPORTANT: Make sure fireplace is 
level before securing. If fireplace is not level 
it will not work properly.
Figure 10 - Installing Horizontal Vent Cap 
(Noncombustible Exterior) 
Wood Screw
Vent Cap
Figure 11 - Installing Siding Standoff 
(Combustible Exterior Wall)
Cut Siding Away to 
Fit Standoff
Wood 
Screw
Screws
Standoff
Vent 
Cap
Apply Mastic
to All Four Sides
Vent Cap
(Horizontal 
Termination)
Interior Wall 
Surface
Wall 
Firestop
Horizontal 
Vent Pipe
Figure 12 - Connecting Vent Cap with 
Horizontal Vent Pipe
Screw