Alcatel-Lucent 6850-48 Guida Di Rete

Pagina di 1162
Remote Monitoring (RMON) Overview
Diagnosing Switch Problems
page 45-10
OmniSwitch AOS Release 6 Network Configuration Guide
September 2009
Remote Monitoring (RMON) Overview
The following sections detail the specifications, defaults, and quick set up steps for the RMON feature. 
Detailed procedures are found in 
.
RMON Specifications
RFCs Supported
2819 - Remote Network Monitoring 
Management Information Base
Platforms Supported
OmniSwitch 6400, 6800, 6850, 6855, and 9000
RMON Functionality Supported
Basic RMON 4 group implementation
–Ethernet Statistics group
–History (Control and Statistics) group
–Alarms group
–Events group
RMON Functionality Not Supported
RMON 10 group*
RMON2*
–Host group
–HostTopN group
–Matrix group
–Filter group
–Packet Capture group
(*An external RMON probe that includes 
RMON 10 group and RMON2 may be used 
where full RMON probe functionality is 
required.)
Flavor (Probe Type)
Ethernet/History/Alarm
Status
Active/Creating/Inactive
History Control Interval (seconds)
1 to 3600
History Sample Index Range
1 to 65535
Alarm Interval (seconds)
1 to 2147483647
Alarm Startup Alarm
Rising Alarm/Falling Alarm/
RisingOrFalling Alarm
Alarm Sample Type
Delta Value/Absolute
RMON Traps Supported
RisingAlarm/FallingAlarm
These traps are generated whenever an Alarm 
entry crosses either its Rising Threshold or its 
Falling Threshold and generates an event con-
figured for sending SNMP traps.