Alcatel-Lucent 6850-48 Manuale Hardware

Pagina di 188
Managing OmniSwitch 6850 Series Stacks
Roles Within the Stack
OmniSwitch 6850 Series Hardware Users Guide
September 2009
page 4-13
To avoid a pass-through condition following a reboot, make sure that all saved slot values for the stack are 
unique. Use th
 command. For example, change the saved slot value for the idle switch in 
slot 3 from 2 to 3:
-> stack set slot 3 saved-slot 2
Use th
 command to verify the change:
-> show stack topology
                                         Link A  Link A          Link B  Link B
NI      Role      State   Saved  Link A  Remote  Remote  Link B  Remote  Remote
                          Slot   State   NI      Port    State   NI      Port
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
   1 PRIMARY     RUNNING    1    UP          3   StackA  UP          2   StackA
   2 SECONDARY   RUNNING    2    UP          1   StackB  UP          3   StackB
   3 IDLE        RUNNING    3    UP          1   StackA  UP          2   StackB
Recovering from Pass-Through Mode (Duplicate Slot Numbers) 
The first step in recovering from pass-through is to determine which modules are currently operating in 
pass-through, as well as the reason for the pass-through state. To view this information, use the 
show stack topology command. For example:
-> show stack topology
                                         Link A  Link A          Link B  Link B
NI      Role      State   Saved  Link A  Remote  Remote  Link B  Remote  Remote
                          Slot   State   NI      Port    State   NI      Port
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
   1 PRIMARY     RUNNING    1    UP       1001   StackA  UP          2   StackA
   2 SECONDARY   RUNNING    2    UP          1   StackB  UP       1001   StackB
1001 PASS-THRU   DUP-SLOT   2    UP          1   StackA  UP          2   StackB
Switches operating in pass-through mode are given distinct slot numbers. These slot numbers are not 
related to their position in the stack. Instead, they are assigned the prefix “100,” followed by the numeri-
cal order in which they were forced into pass-through (1001–1008).
Note. For pass-through elements 1001 through 1008, the slot indicator LED on the chassis front panel 
blinks 1 through 8, respectively. For example, if a module enters pass-through and has the slot number 
1004, the LED for the module blinks the number 4. For more information on the slot indicator LED, refer 
to 
.
In the example above, the switch with the NI (i.e., slot) number 1001 is operating in pass-through. Note 
that the role assignment is PASS-THRU; also, the state displays DUP-SLOT, or duplicate slot number
This can be further verified by looking down the saved slot column in the table. Note that slot 2, operating 
in the secondary management role, has a saved slot value of 2. Slot 1001, operating in pass-through, also 
has a saved slot value of 2.