Managing OmniSwitch 6850 Series Stacks
Roles Within the Stack
OmniSwitch 6850 Series Hardware Users Guide
September 2009
page 4-13
To avoid a pass-through condition following a reboot, make sure that all saved slot values for the stack are
unique. Use the
unique. Use the
slot 3 from 2 to 3:
-> stack set slot 3 saved-slot 2
Use the
command to verify the change:
-> show stack topology
Link A Link A Link B Link B
NI Role State Saved Link A Remote Remote Link B Remote Remote
Slot State NI Port State NI Port
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
1 PRIMARY RUNNING 1 UP 3 StackA UP 2 StackA
2 SECONDARY RUNNING 2 UP 1 StackB UP 3 StackB
3 IDLE RUNNING 3 UP 1 StackA UP 2 StackB
Link A Link A Link B Link B
NI Role State Saved Link A Remote Remote Link B Remote Remote
Slot State NI Port State NI Port
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
1 PRIMARY RUNNING 1 UP 3 StackA UP 2 StackA
2 SECONDARY RUNNING 2 UP 1 StackB UP 3 StackB
3 IDLE RUNNING 3 UP 1 StackA UP 2 StackB
Recovering from Pass-Through Mode (Duplicate Slot Numbers)
The first step in recovering from pass-through is to determine which modules are currently operating in
pass-through, as well as the reason for the pass-through state. To view this information, use the
show stack topology command. For example:
pass-through, as well as the reason for the pass-through state. To view this information, use the
show stack topology command. For example:
-> show stack topology
Link A Link A Link B Link B
NI Role State Saved Link A Remote Remote Link B Remote Remote
Slot State NI Port State NI Port
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
1 PRIMARY RUNNING 1 UP 1001 StackA UP 2 StackA
2 SECONDARY RUNNING 2 UP 1 StackB UP 1001 StackB
1001 PASS-THRU DUP-SLOT 2 UP 1 StackA UP 2 StackB
Link A Link A Link B Link B
NI Role State Saved Link A Remote Remote Link B Remote Remote
Slot State NI Port State NI Port
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
1 PRIMARY RUNNING 1 UP 1001 StackA UP 2 StackA
2 SECONDARY RUNNING 2 UP 1 StackB UP 1001 StackB
1001 PASS-THRU DUP-SLOT 2 UP 1 StackA UP 2 StackB
Switches operating in pass-through mode are given distinct slot numbers. These slot numbers are not
related to their position in the stack. Instead, they are assigned the prefix “100,” followed by the numeri-
cal order in which they were forced into pass-through (1001–1008).
related to their position in the stack. Instead, they are assigned the prefix “100,” followed by the numeri-
cal order in which they were forced into pass-through (1001–1008).
Note. For pass-through elements 1001 through 1008, the slot indicator LED on the chassis front panel
blinks 1 through 8, respectively. For example, if a module enters pass-through and has the slot number
1004, the LED for the module blinks the number 4. For more information on the slot indicator LED, refer
to
blinks 1 through 8, respectively. For example, if a module enters pass-through and has the slot number
1004, the LED for the module blinks the number 4. For more information on the slot indicator LED, refer
to
.
In the example above, the switch with the NI (i.e., slot) number 1001 is operating in pass-through. Note
that the role assignment is PASS-THRU; also, the state displays DUP-SLOT, or duplicate slot number.
This can be further verified by looking down the saved slot column in the table. Note that slot 2, operating
in the secondary management role, has a saved slot value of 2. Slot 1001, operating in pass-through, also
has a saved slot value of 2.
that the role assignment is PASS-THRU; also, the state displays DUP-SLOT, or duplicate slot number.
This can be further verified by looking down the saved slot column in the table. Note that slot 2, operating
in the secondary management role, has a saved slot value of 2. Slot 1001, operating in pass-through, also
has a saved slot value of 2.