Chapter
4
SENSOR SETUP Menu
Cal in Peel Mode
This option allows you to perform a calibration (Run Auto-Cal or Pwr Up 
Auto-Cal) in Peel-Off Media Handling mode.
Disable (factory default). The printer will not permit calibration and a
“CANNOT CALIBRATE/Disable Peel-Off” message will briefly display. 
Additionally, if “Pwr Up Auto-Cal” is enabled, the printer will not perform 
calibration at power up.
Enable. Run Auto-Cal can be performed from the front panel, and if the 
Pwr Up Auto-Cal option is enabled, calibration will be performed at power 
up.
NOTE: Calibration in Peel-Off mode does not stop and wait for you to remove 
peeled labels. Therefore, be prepared to remove the labels as they 
are automatically peeled.
Min Calib Delta
Minimum Calibrate Delta changes the minimum threshold value the sensor(s) 
require to detect the difference between the label and a gap, notch, hole or 
black mark. This allows bolder gaps (such as notches or holes) to be used as 
the TOF while intermediate gaps (liner) can be ignored. Increasing the Min 
Calib Delta makes the sensor(s) less sensitive to intermediate gaps and 
noise. Decreasing the Min Calib Delta makes the sensor(s) more sensitive for 
detecting gaps on low contrast media, where there is very little difference 
between the label and the gap (liner).
The range is 012 - 050. The factory default is 20.
Use Label Length
Determines whether or not the Label Length value set in the MEDIA SETUP 
menu is used during Run Auto-Cal.
Disable (factory default). Run Auto-Cal relies exclusively in its ability to 
detect varying transitions between labels and gaps, notches, holes, or 
black marks while advancing media during the calibrate process to 
determine Sensed Distance. The amount of media advanced is based on 
the number of transitions detected.
NOTE: Although the “Use Label Length” keeps its value (enable/disable) at 
all times, it will always be disabled when “Set Label Length” is set to 
“Automatic”. The correct setting will take effect when “Set Label 
Length” is set to manual. Based on the setting on the “Set Label 
Length” menu in the Media Setup menu, the “Use Label Length” 
menu will be ignored (disabled).
Enable. The Label Length value set in the MEDIA SETUP menu is used 
in the calibrate algorithm. This causes the Run Auto-Cal process to 
advance media the minimum distance required to detect the true gap, 
notch, hole, or black mark used for TOF (Top-of-Form) sensing. This 
resolves problems where the sensor(s) may mistake high noise levels or 
preprinted images within the label as the gap, notch, hole, or black mark 
that could result in a sensed distance value much shorter than the actual 
label length. Example: A 0.2 inch calibrated Sensed Distance with a 3.0 
inch long label installed.