 Unit Installation
NetVanta 3000 Series Hardware Installation Guide
 76
Copyright © 2010 ADTRAN, Inc.
61200860L1-34AA
Mounting Options
The NetVanta 3120, NetVanta 3130, and NetVanta 3200 can be installed in a wallmount or tabletop 
configuration. The NetVanta 3205 and NetVanta 3305 can be installed in a tabletop, wallmount, or 19-inch 
rackmount configuration. The NetVanta 3430 and NetVanta 3448 can be installed in a tabletop or 
rackmount configuration.
For tabletop mounting, you can attach rubber mounting feet to the bottom of the unit if desired. The 
following sections provide step-by-step instructions for rack mounting and wall mounting.
Rack Mounting NetVanta 3000 Series
The NetVanta 3205, NetVanta 3305, NetVanta 3430, NetVanta 3448, NetVanta 3450, and NetVanta 3458 
are 1U-high, rack-mountable units that can be installed into 19-inch equipment racks. Follow these steps to 
mount the NetVanta 3000 Series unit into a rack:
If you have purchased P/N 4200368L1, which includes the VPN Accelerator Card with the 
NetVanta 3305, install the card before mounting the unit. Refer to 
.
Instructions for Rack Mounting the NetVanta 3000 Series
Step
Action
1
To allow proper grounding, scrape the paint from the rack around the mounting holes where the NetVanta 
3000 Series will be positioned.
2
Position the NetVanta 3000 Series in a stationary equipment rack. This unit occupies 1U of space. 
3
Have an assistant hold the unit in position as you install two mounting bolts through the unit’s brackets and 
into the equipment rack using a #2 phillips-head screwdriver.
4
Proceed to the steps given in 
.
If installed in a closed or multi-unit rack assembly, the operating ambient temperature 
of the rack environment may be greater than room ambient temperature. Therefore, 
consideration should be given to installing the equipment in an environment compatible 
with the maximum ambient temperature specified by the manufacturer.
Installation of the equipment in a rack should be such that the amount of air flow 
required for safe operation of the equipment is not compromised.
Be careful not to compromise the stability of the equipment mounting rack when 
installing this product.
Consideration should be given to the connection of the equipment to the supply circuit 
and the effect that overloading the circuit might have on overcurrent protection and 
supply wiring. Appropriate consideration of equipment nameplate ratings should be 
used when addressing this concern.
Reliable grounding of rack-mounted equipment should be maintained. Particular 
attention should be given to supply connections other than direct connections to the 
branch circuit (e.g., use of power strips).