Enterasys csx200 Guida Utente

Pagina di 261
10BASE-T LAN Requirements
22
CSX200 Family User’s Guide
Temperature —
Multi-pair PVC 24 AWG telephone cable typically has an attenuation of 
approximately 8–10 dB/100 m at 20
°
C (68
°
F). The attenuation of PVC insulated cable varies with 
temperature. At temperatures greater than 40
°
C (104
°
F), use plenum-rated cable to ensure that 
attenuation remains within specification.
Port Descriptions
Table 1 Ethernet Twisted Pair Ports (1-12)
10BASE-T LAN Configuration
This section contains the procedures for connecting a UTP segment from the 10BASE-T network 
or other devices to the CSX200. Ports 1 through 12 on the CSX200 have RJ45 connectors for UTP 
connections. 
Pin Number
Signal Name
1
Twisted Pair 
Transmit +
2
Twisted Pair 
Transmit -
3
Twisted Pair 
Receive +
4
Ground
5
Ground
6
Twisted Pair 
Receive -
7
Ground
8
Ground