CAUTION
Electrical installation must observe all state and 
local codes. This unit requires connection to a 
grounded (three-prong), polarized receptacle that 
has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 
Hz, 15A power supply (normal household current). An 
individual, properly grounded branch circuit or circuit 
breaker is recommended. GFCI (ground fault circuit 
interrupter) is usually not required for fixed location 
appliances and is not recommended for your unit because 
a GFCI could be prone to nuisance tripping. However, be 
sure to consult your local codes.
See Figure 13 for recommended receptacle location. 
Plugging the unit into a receptacle located behind an 
adjacent cabinet will allow the CLRCO2175 to be more 
easily serviced with self-diagnostics without disturbing 
your installation.
Figure 13
WARNING
SHOCK HAZARD — Electrical Grounding Required. 
• Never remove the round grounding prong from 
the plug and never use a two-prong grounding 
adapter.
• Never use an extension cord to connect power to 
the unit.
Note: Unit is shipped in the “ON” position and only needs 
to be plugged in to start up.
Figure 14
IMPORTANT
IMPORTANT
Proper air flow (Figure 14) is required for your unit 
to operate at its highest efficiently. A grille, located 
in the base of the unit, must not be blocked at any 
time, or your unit will not perform as expected.
Figure 15
All U-Line units are shipped with controls that are preset. 
No initial adjustments are required. 
1. Open the door and remove the cover in front of the 
evaporator by gently compressing and pulling 
forward. This will enable you to observe the water 
flow over the evaporator.
2. Check that the overflow tube is inserted securely into 
the water trough. PLUG UNIT IN. Once the unit is 
powered up, the water fill valve will energize and fill 
the water reservoir. The water fill valve shuts off after 
approximately 180 seconds (3 minutes). The compressor 
begins to operate.
The CLR2160 display will show “ICE” when the unit is on 
and will show “OFF” when the unit is off.
The CLRCO2175 display will show the set-point 
temperature (38°F) when the unit is on and will show 
“OFF” when the unit is off (Figure 15) .
Watch the water flow over the evaporator assembly (ice 
cube tray) to familiarize yourself with the operation. 
Upon initial start-up, water flow ove the evaporator 
may be uneven. This may cause uneven sized cubes or 
water spilling into the ice storage bin. This is normal 