8. When water begins flowing over the evaporator 
(approximately 3 minutes), pour 1 packet of CLR cleaner 
into the water trough. The cleaning process will last 
approximately 45 minutes.
Figure 23
9. Following the cleaning process, sanitize the ice bin with 
a bleach solution.
Dilute 1 tablespoon bleach in 1 gallon of warm water. 
Apply this solution to the entire inside of the storage 
area. Then rinse thoroughly with water.
The unit will resume operation approximately 15 minutes 
after the automated cleaning process is completed. The 
water fill valve will energize, fill the water reservoir, and 
shut-off after three minutes. The compressor begins to 
operate and water flows over the evaporator assembly 
(ice cube tray). Initially, the water flow may not be 
uniform, causing uneven sized cubes or water to spill into 
the ice storage bin. This is a normal situation that will 
correct itself within the first 24 hours of operation. 
IMPORTANT
IMPORTANT
• Discard all ice produced in the first harvest.
• Should power to the unit be interrupted during 
the self-clean cycle, it will be necessary to repeat 
the complete cleaning cycle after power is 
restored. 
Ice Cube Thickness Adjustment
INTERVAL - AS REQUIRED
Ice thickness adjustments are made using the control 
panel as follows:
1. To enter the thickness adjustment mode:
a. Touch and hold the UP ARROW button.
b. Touch and release the DOWN ARROW button three 
times, then release the UP ARROW button.
c. The display will switch to “0” to confirm the 
thickness adjustment mode has been selected.
2. The factory setting is “0,” and the total range of 
adjustment is -5 to +5 (ideal range is -1 to +1). Use the 
UP ARROW button to raise the setting and thicken the 
ice bridge, or the DOWN ARROW button to lower the 
setting to thin the ice bridge.
IMPORTANT
IMPORTANT
Ice thickness adjustment should only be made one 
increment at a time. Allow ice maker production to 
stabilize for 24 hours before rechecking ice 
thickness.
3. Touch and release the LIGHT button key to exit the ice 
thickness adjustment mode.
4. Remove all ice from the storage bin.
Figure 24
Ice cubes in any given batch will vary, so it is necessary to 
choose cubes from the sample area for comparison when 
making adjustments. If further adjustments are desired, 
repeat Steps 1 through 4.
The ice cube thickness is factory set for best overall 
performance. The factory setting is designed to maintain 
an ice bridge of approximately 1/16" to 1/8" under normal 
conditions resulting in a dimple of approximately 1/4" to 
1/2" in depth. A fuller cube with less of a dimple results in 
a thicker ice bridge. As the ice bridge becomes thicker, the 
tendency for the cubes to stay together as a slab 
increases. A bridge thicker than 1/8" may cause cubes to 
overfill the ice bucket.
Brush
DIMPLES
ULIN_0299_A
ICE BRIDGE
Ice Bridge and Dimples