U-Line clrco2175b40 Guida Utente

Pagina di 28
CLR2160, CLRCO2175
17
Door Alignment Check and 
Adjustment
IMPORTANT
IMPORTANT
When properly aligned:
• The door will not be flush with the top of the 
cabinet. The top edge of the door will be 1/8” 
(3.175 mm) below the cabinet top.
• The door gasket will be firmly in contact with the 
perimeter of the cabinet and not pinched on the 
hinge side of the door.
The following procedure will correct for up to 1/4” 
misalignment:
Figure 29
1. Compare the top edge of the door (opposite the 
hinges) to the top edge of the cabinet (Figure 29) and 
note the type (up or down) of adjustment needed.
Figure 30
2. Remove the top hinge pivot pin with a Phillips 
screwdriver (Figure 30) and lift door off bottom hinge 
pin. Be careful not to lose the door closer insert sets. 
Figure 31
3. Turn the door upside down and inspect the hinge plate 
mounting holes. 
• Your plate has slotted mounting holes (Figure 31)
Loosen but do not remove the two hinge plate 
screws.
4. If door edge opposite the hinges needs to move up, 
move plate toward outside of door. If door edge needs 
to move down, move plate toward inside of door. 
Repeat until top edge of door is parallel with top of 
cabinet and tighten screws securely. 
Figure 32
5. After adjustment is complete, remove the door closers 
from the bottom hinge, clean thoroughly and apply 
petroleum jelly to the mating surfaces of the closers. Be 
sure that bosses on closers (Figure 32) align with holes 
in the door and bottom cabinet hinge plates. Mount 
door and install top hinge pivot pin.
1/8"
(3.175 mm)
ULIN_0016_A
ULIN_0133_A
ULIN 0201 A
Slotted 
mounting 
holes
toward outside of door
toward inside of door
Door closer inserts
ULIN_0004_A