U-Line clrco2175s01 Manuale Utente

Pagina di 20
U-Line Ice Makers
9
The unit will resume operation approximately 15 minutes after the 
automated cleaning process is completed. The water fill valve will 
energize, fill the water reservoir, and shut-off after three minutes. 
The compressor begins to operate and water flows over the 
evaporator assembly (ice cube tray). Initially, the water flow may 
not be uniform, causing uneven sized cubes or water to spill into 
the ice storage bin. This is a normal situation that will correct itself 
within the first 24 hours of operation. 
IMPORTANT
IMPORTANT
• Discard all ice produced in the first harvest.
• Should power to the unit be interrupted during the 
self-clean cycle, it will be necessary to repeat the 
complete cleaning cycle after power is restored. 
Ice Cube Thickness Adjustment
Interval - As Required
Ice thickness adjustments are made using the control panel as 
follows:
1. To enter the thickness adjustment mode:
• Touch and hold the UP ARROW button.
• Touch and release the DOWN ARROW button three times, 
then release the UP ARROW button.
• The display will switch to “0” to confirm the thickness 
adjustment mode has been selected.
2. The factory setting is “0,” and the total range of adjustment is -5 
to +5 (ideal range is -1 to +1). Use the UP ARROW button to 
raise the setting and thicken the ice bridge, or the DOWN 
ARROW button to lower the setting to thin the ice bridge.
IMPORTANT
IMPORTANT
Ice thickness adjustment should only be made one 
increment at a time. Allow ice maker production to 
stabilize for 24 hours before rechecking ice thickness.
3. Touch and release the LIGHT button key to exit the ice 
thickness adjustment mode.
4. Remove all ice from the storage bin.
Ice cubes in any given batch will vary, so it is necessary to choose 
cubes from the sample area for comparison when making 
adjustments. If further adjustments are desired, repeat Steps 1 
through 4.
The ice cube thickness is factory set for best overall performance. 
The factory setting is designed to maintain an ice bridge of 
approximately 1/16" to 1/8" under normal conditions resulting in a 
dimple of approximately 1/4" to 1/2" in depth. A fuller cube with 
less of a dimple results in a thicker ice bridge. As the ice bridge 
becomes thicker, the tendency for the cubes to stay together as a 
slab increases. A bridge thicker than 1/8" may cause cubes to 
overfill the ice bucket.
DIMPLES
ICE BRIDGE
Ice Bridge and Dimples
GOOD
BRIDGE
TOO THIN
BRIDGE
TOO THICK
DIMPLE
TOO DEEP
LITTLE OR
NO DIMPLE
1/4" TO 1/2"
DIMPLE
1/16" TO 1/8"
ICE BRIDGE
BAD
Cube Types