U-Line clrco2175s01 Manuale Utente

Pagina di 20
10
U-Line Combo® Models and Ice Makers Maintenance
1
6 Maintenance
For Models with adjustable leveling feet:
1. Use a level to check the levelness of the unit from front to back 
and from side to side. Place the level along top edge and side 
edge as shown (1).
2. If the unit is not level, rotate the adjustable leveling legs to raise 
or lower each corner of the unit (5) as necessary.
3. Check levelness after each adjustment and repeat the previous 
steps until the unit is level.
Leveling
IMPORTANT
IMPORTANT
Unit must be level, for proper door and ice maker (if 
equipped) operation. 
Removing and Installing Interior Shelves
1. Pull shelf out about 6" (Figure 
40) until back of shelf clears 
the "hump" on the right-hand 
side.
2. Tilt right-hand edge of shelf 
up. Remove shelf from unit by 
pulling out.
Insert the shelves as follows:
1. To move to a different 
position in the unit, insert 
shelf at an angle, 
approximately 15°-20°, over 
the rib in the side of the unit 
where you want to place the 
shelf. The shelf must be started into the unit at an angle to 
clear the door.
2. Continue to slide the shelf into the unit at an angle until it clears 
the door.
3. Lower the shelf and push it in completely.
1
2
For Models without adjustable leveling feet:
IMPORTANT
IMPORTANT
The unit must be located on a level surface, for proper 
door and ice maker (if equipped) operation. 
Use a level to check the levelness of the unit from front to back 
and from side to side. Place the level along top edge and side 
edge as shown (1).
Lightbulb Replacement
To replace the lightbulb in your U-Line unit:
1. Find the light located at the top of the unit. Grasp the edges of 
the light housing lens (1) opposite the exposed tab and gently 
push the lens toward the tab (2).
2. Pull the edge of the lens down (1) and swing it out of the light 
housing.
IMPORTANT
IMPORTANT
ALWAYS use a genuine U-Line replacement 120V 10 watt 
bulb (Part Number 31317) in the light housing. Use of any 
other bulb within the housing will produce excessive heat, 
causing damage to the light housing and cabinet interior, 
and will compromise the precise temperature control of 
the unit.
1. Replace the lens by first inserting the tab side back into the 
housing at a slight angle. 
2. While gently pushing the lens towards the tab end, push the free 
end into the housing, and release when you hear a snap.
1
2
CLRCO2175 Only