Bizfon 2000 Guida Utente

Pagina di 106
Bizfon Manual II: Administrator's Guide  
Administrator’s Menus 
Bizfon2000 and Bizfon4000 (SW Version 4.1.x) 
 
26
 
• 
Clickatell – this selection allows to use a pre-defined SMS gateway. Selection enables the API ID text field which indicates a Clicatell specific 
parameter obtained from the server and should match on both sides. 
• 
Custom – this selection allows to use a custom SMS gateway. Selection requires following parameters to be inserted: 
Resource text field requires the HTTP resource name on the SMS gateway, for example: /http/sms.cgi. 
Parameters text field requires the parameters to be submitted to the resource address. The value of this field represents a string 
with tokens (separated by percent (%) symbols) inside. Each token indicates a value of the certain field on this page. The value is 
dependent on the SMS gateway requirements. For example: 
 
user=%username%&password=%password%&to=%to%&from=%from%&text=%text% 
 
The tokens are the strings that have the following dependencies from the field in this page: 
 
%username% – indicates the username defined in the field Username 
%password% – indicates the password defined in the field Password 
%to% - indicates the password defined in the field SMS Recipient Address 
%from% - indicates the password defined in the field SMS Sender Address 
%text% - indicates the SMS text generated by Bizfon (voice mail notification, event notification, etc.) 
 
Server text field requires the IP address or the host name of the SMS gateway. 
Port text field requires the port number of the SMS gateway. 
Use Secure HTTP checkbox enables access to SMS server via HTTPS. Checkbox selection enables a Secure Port text field that 
requires the port number for HTTPS traffic. 
Request Method manipulation radio buttons allow to select the HTTP request method used by Bizfon the access the SMS 
gateway: POST or GET. 
 
Send Test SMS is used to send a test SMS to the defined SMS Recipient Address.  This button will be enabled if correct values have been 
submitted and saved on this page. 
 
Firmware Update 
This window allows updating the software of Bizfon by installing new firmware (image). Users registered at Bizfon will receive a notice when new 
firmware is available.  
Updating new firmware requires a working power supply. Bizfon is provided with a battery (accumulator). If the battery is low or simply absent the 
“There is no battery or voltage is low” warning is displayed.
 
 
Please Note:
  Installing new firmware will take about 15 
minutes. During this time, Bizfon, telephony and Internet 
access will be disabled. 
The firmware update will cause the loss of the following 
data: 
• 
All internally stored voice mails and custom voice 
messages 
Please Note:
 If you do not wish to lose your voice data, 
have it downloaded from 
 
page prior to starting the Firmware Update. 
• 
DHCP leases
 
• 
Transfer
 
statistics
 
• 
Call statistics
 
Please Note:
 If you consider the 
 entries in 
the displayed tables to be important, it is recommended 
to download them from the corresponding page prior to 
starting the Firmware Update. 
 
Fig. II-43: Firmware Update page 1 
• 
All
 
pending
 
events
 
• 
User
 
specific
 
GUI
 
states
 
The following main processes will be stopped during the firmware update and will be restarted after the installation is completed: 
• 
Voice
 
Software
 
• 
Network
 
Time
 
Protocol
 
Daemon
 
• 
Network
 
Interface
 
Statistic
 
Daemon
 
• 
Dynamic
 
DNS
 
Daemon
 
 
Next will move you to the second page of Firmware Update where the image file should be selected.