Clavia electro 2 Guida Utente

Pagina di 64
NORD ELECTRO 2 V3.0x
5. Panel reference: System functions
Page 35
the Nord Electro 2’s MIDI In. Since the sequencer echoes back incoming MIDI data, Nord Electro 2 will 
respond normally to your playing and knob tweaking via the MIDI “loop”. If you use Local On in the se-
quencer setup described above, you will get double-notes when you play: from the keyboard internally and 
via the MIDI “loop”. This is not what you want. Therefore, always use Local Off together with sequencers.
Select Local On or Local Off with the U
P
/D
OWN
 N
AVIGATOR
 buttons. Press any button (except for the 
S
HIFT
, S
TORE
 or U
P
/D
OWN
 buttons) to exit. Note that ‘Local Off’ is not saved, so you will have to 
reconfigure after power off.
T
UNE
The Master Tune function is global for all sounds in Nord 
Electro 2, i.e. changing it will affect all Programs. Press the 
S
HIFT
 + P
ROGRAM
 4 (TUNE) buttons to enter the Master 
Tune function.
1. Change the master tune, in cents, with the U
P
/D
OWN
 
N
AVIGATOR
 buttons. ‘0’ is normal 440Hz tuning. The 
range is +/- 1 semitone in steps of 1 cent (hundreds of 
a semitone).
2. Press any button (except for the S
HIFT
, S
TORE
 or U
P
/
D
OWN
 buttons) to exit.
M
EM
 L
OCK
Press the S
HIFT
 + P
ROGRAM
 5 (MEM LOCK) buttons to 
enter the Memory Lock function. Here you can choose to 
memory protect all Programs of the internal memory. Select 
Memory Protect ‘On’ or ‘OF’ with the U
P
/D
OWN
 N
AVIGA
-
TOR
 buttons. Press any button (except for the S
HIFT
S
TORE
 or U
P
/D
OWN
 buttons) to exit.
Note! When Nord Electro 2 is shipped from factory, 
Memory Lock is set to ‘On’. To be able to store Pro-
grams (and receive MIDI Sysex dumps), set Memory 
Lock to ‘OF’.