Nortel 1000 Guida Utente

Pagina di 256
245
Appendix B
Product integrity
Environmental specifications
ICB environmental requirements meet, or exceed, Meridian system
requirements. The power provided for each card slot in the IPE module
exceeds the power requirements for an ICB.
shows the range of acceptable temperatures and
humidity for the ICB.
Table 63
ICB environmental specifications
Specification
Minimum
Maximum
Recommended
Temperature
15
C
30
C
Relative humidity
10%
55%
(non-condensing)
Absolute
Temperature
0
C
45
C
Relative humidity
5% to
95%
(non-condensing)
Normal Operation
Rate of change
Less than 1
C per 3 minutes
Long Term
Temperature
- 40
C
70
C
Relative humidity
0%
95%
(non-condensing)
- 40
C to 70
C, non-condensing
Short Term (less than 72 hr.)
Storage
Temperature
- 40
C
70
C
Temperature Shock
In three minutes
- 40
C to
25
C
Nortel Communication Server 1000/Communication Server 2100 Solution/Meridian SL-100
Nortel Integrated Conference Bridge: Service Implementation Fundamentals
NN43001-558/555-4001-135
01.02
Standard
ICB Release 4
20 June 2007