5
Mounting the wall bracket 
•  Secure the wall bracket directly to the wall and into wall  studs
using screws provided as shown in figure 3
•  Make sure the wall bracket is horizontally level when mounted
•  If wall studs are not available, it is recommended to  use a toggle 
bolt or similar drywall anchor
•  If you are mounting the bracket on a concrete wall, use anchor
bolts to secure the top of the bracket to the wall
Do not overtighten the bottom two screws causing the bracket
to bend. There should be a .20 inch gap between the bracket
and wall
CAUTION
Make sure the wall bracket is level. 
If the wall unit is not mounted level, condensate water will leak
from the unit and can damage walls and/or carpet underneath.
INDOOR UNIT INSTALLATION
11
3
Minimum 5.5”
to ceiling
Minimum 5.5”
to wall
Minimum  7”
to wall
Fasten wall bracket to wall studs with screws
Drill a 2.5” diameter tubing hole at either the right or the
left. The hole should be slightly slanted to the outdoor
side. Your application may vary. See figure 4 for different
tubing outlet location options.
Drill the tubing access hole
Drill a 2.5” diameter tubing
access hole to route the
tubing to the outdoor unit.
The hole should be slightly
slanted to the outdoor side. 
A typical installation will use a
Right or Left back outlet as
illustrated in figure 3.  
See figure 4 for  different
configurations to suit your
application. 
Left Bottom Outlet
Left Back Outlet
Left Outlet
Right Bottom Outlet
Right Back Outlet
Right Outlet
11
4
There should be a .20 inch gap
between the bracket and wall
Side view