3com S7906E Guida Di Riferimento
3-4
When the total number of error frames and error frame rate of the data transferred between the OLT and
ONU exceed the alarm thresholds, the frame error rate alarm occurs.
By default, both uplink and downlink data between OLT and ONU are monitored.
Related commands: alarm frame-error-rate enable.
Examples
# Enable the frame error rate alarm on OLT 1/0/1, adopt the default monitor direction, and set the
corresponding alarm threshold to 20.
<Sysname> system-view
[Sysname] interface olt 1/0/1
[Sysname-Olt1/0/1] alarm frame-error-rate direction up-down-link threshold 20
alarm frame-error-rate enable
Syntax
alarm frame-error-rate enable
undo alarm frame-error-rate enable
View
OLT port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm frame-error-rate enable command to enable the frame error rate alarm.
Use the undo alarm frame-error-rate enable command to disable the frame error rate alarm.
By default, the frame error rate alarm is enabled.
Examples
# Enable the frame error rate alarm on OLT 3/0/1.
<Sysname> system-view
[Sysname] interface olt 3/0/1
[Sysname-Olt3/0/1] alarm frame-error-rate enable
alarm llid-mismatch enable
Syntax
alarm llid-mismatch enable
undo alarm llid-mismatch enable
View
OLT port view, FTTH view