Canon LV-7380 Manuale

Pagina di 96
38
4. Convenient Features
 Lamp Mode and Energy-Saving Effect
Selecting [Quiet] for Lamp mode will help you to reduce CO
2
 emissions from the projector. 
The Lamp mode enables you to select two brightness modes of the lamp: Normal and Quiet modes. The lamp life 
can be extended by using the Quiet mode.
Lamp Mode
Description
Status of LAMP indicator
Normal Mode
This  is  the  default  setting  (100% 
Brightness).
Off
Quiet Mode
Select  this  mode  to  increase  the 
lamp  life  (LV-7385/LV-8310/LV-8215: 
approx.75%  Brightness/LV-7380/LV-
7285/LV-7280:  approx.80%  Bright-
ness).
Steady Green 
light 
Changing Lamp Mode
To change the [Lamp mode] from [Normal] to [Quiet], do the following:
1.  Press the MENU button on the remote control to display the menu.
2.  Select [Setup]
→ [General] → [Lamp mode].
3.  Press the ENTER button to display the Lamp mode menu. 
4.  Press the   button to select [Quiet] and press the OK button.
5.  Press the OK button to close the menu.
 
NOTE:
•  The projector has the Eco message function that will show the status of Quiet mode on screen. Select [Setup] [Menu]  [Eco 
message] [On].See page
.
•  The lamp life remaining and lamp hours used can be checked in [Usage time]. Select [Information] [Usage time]. See page
.
•  The projector will only operate in the [Quiet] mode for 90 seconds immediately after the lamp is turned on.
 The lamp condition will not be affected even when [Lamp mode] is changed.
•  If there is no signal for about one minute, the projector will display a blue, black or logo background (depending on setting)
and go into [Quiet].
 The projector will return to the [Normal] mode once a signal is accepted.
•  If the projector is overheated in Normal mode, there may be a case where the Lamp mode automatically changes to Quiet
mode to protect the projector. This is called “forced cooling operation”. When the projector is in a forced cooling operation, 
the picture brightness decreases. When the projector comes back to normal temperature, the Lamp mode returns to Normal
mode.
  Thermometer symbol [ ] indicates the lamp mode is automatically set to a forced cooling operation because the internal
temperature is too high. In this condition, changing [Lamp mode] setting in the menu will not affect the actual lamp mode
and the LAMP indicator lights green.