Xerox 4213 MICR MRP Guida Utente

Pagina di 315
SPECIAL FEATURES
Filter mode
The Filter mode is invoked when the Filter mode entry string is
detected in the datastream. Filter mode provides a method of
sending text, fonts, and graphics to the printer without being
corrupted by IBM commands. Once in the Filter mode, all
EBCDIC IBM single-byte and multibyte commands and
parameters are removed from the datastream.
The default value is:
@Y36,1@
It is terminated when the Filter mode exit string is detected. 
The default value is:
@Y36,0@
To change the default value for entering and exiting the Filter
mode, use the following escape sequences:
Set Enter Filter Mode
@Y200,'<string>'@ 
Set Exit Filter Mode
@Y201,'<string>'@
  
@
The interface escape character
Y200
The command that sets Enter Filter mode
Y201
The command that sets Exit Filter mode
, (comma)
The command delimiter
'<string>'
The command string used to enter or exit the
Filter mode. A single or double quote must
begin and end the string.
The strings, up to eight characters long, must
not be the same for different mode strings, but
can be the same for the enter and exit strings of
a particular mode.
An attempt to set the string for one mode to be
the same as for another, or to be the same as
the interface escape character, causes the
command to be rejected. 
@
The interface escape character
3–20