Cisco Cisco Unified MeetingPlace Audio Server Manuale Di Manutenzione
4-71
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8106)
78-16411-01
Chapter 4 Configuring the 8106 Server
Configuring the system
Step 7
Type the correct slot number for the blade you want to modify and press Enter. In this configuration, it
is slot 6 so type
is slot 6 so type
6
and press Enter.
Figure 4-77 Setting IP Address for 120 E1 and 120 IP Ports
Step 8
Continue pressing Enter until you are prompted to enter the IP address, as shown in line 15 of
Step 9
Enter the correct IP address and continue pressing Enter until you are prompted with the “blade”
configuration menu.
configuration menu.
Step 10
Type
2
and press Enter to modify a blade. A prompt for the blade slot to modify appears, as shown in
line 8 in
Step 11
If it is correct, type
x
and press Enter to exit the program. If not, repeat the steps above.
***** B L A D E C O N F I G M E N U *****
1) View blade details
2) Modify blade
x) Exit program
Enter command: 2
Enter blade slot [1..6]: 6
Type [IP]:
Card Type [ TP1610]:
Port Group [ 1]:
Number of Ports [120]:
1st Port [ 120]:
IP address [0] [0.0.0.0]: 10.10.10.10
Subnet Mask [0.0.0.0]: 255.255.255.0
Default Gateway [0.0.0.0]: 10.10.10.1
Base UDP Port [0] [ 5000]:
Jitter Buffer Minimum Size [ 100]:
Jitter Buffer Optimization [ 7]:
IP Precedence [0]:
Type of Service (TOS) [ 0]:
DSCP / DiffServ [unused]:
RTCP Interval [default]: