Cisco Cisco StadiumVision Director Manuale Di Manutenzione
© 2011 Cisco Systems, Inc. All rights reserved.
Page 11 of 20
Figure 6.
Configuring Email Notification Through the Director Configuration Screen
3. Edit the following settings:
Table 3.
Configuring Registry Settings for Email Notification
Configuration Property
Value
Registry Setting
Enable Email notification?
Used to enable / disable StadiumVision Director from
sending emails. Values: Yes/No. Yes means emails
will be sent to the recipients.
sending emails. Values: Yes/No. Yes means emails
will be sent to the recipients.
hpm.email.sendEmail
SMTP Host
The ip address / DNS name of the SMTP email
server. This is site specific and must be configured by
the customer or Cisco staff that is installing /
configuring StadiumVision at the customer site.
server. This is site specific and must be configured by
the customer or Cisco staff that is installing /
configuring StadiumVision at the customer site.
hpm.email.SMTPHost
Recipient list
Comma separated list of email recipients who will
receive the report.
receive the report.
hpm.email.Recipients
From address to use
The email sender name (default is SV-email-notifier)
hpm.email.from
Default Subject Text
Default subject field. Usually, StadiumVision Director
will replace the default subject field with a content-
specific subject.
will replace the default subject field with a content-
specific subject.
hpm.email.subject
Email ID Prefix
The email subject will be prefixed with this id. This
makes it easier to handle reports / emails from multiple
sites. This is primarily for Cisco support engineers who
may receive email alerts from multiple customers.
makes it easier to handle reports / emails from multiple
sites. This is primarily for Cisco support engineers who
may receive email alerts from multiple customers.
hpm.email.id
Here is an example of the detailed report that is generated by StadiumVision
Director and sent as an email attachment:
Director and sent as an email attachment:
StadiumVision Health Report generated at: 2010-02-18 04:37:37 PM
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
-----------------------------------------------------------------------------
Total number of DMPs: 15
Total number in Normal State: 5
Total number in Critical State: 10
Total number in Normal State: 5
Total number in Critical State: 10
Total number in Unknown State: 0
Total number rebooted: 0
Total number rebooted: 0